30080 Parallax Inc, 30080 Datasheet
30080
Specifications of 30080
Available stocks
Related parts for 30080
30080 Summary of contents
Page 1
... Copyright © Parallax Inc. Web Site: www.parallax.com Forums: forums.parallax.com Sales: sales@parallax.com Technical: support@parallax.com Parallax Say It Module (#30080) Office: (916) 624-8333 Fax: (916) 624-8003 Sales: (888) 512-1024 Tech Support: (888) 997-8267 v1.0 4/14/2010 Page ...
Page 2
... Vdd at bottom P0 and LED to P4). 2. Download and install the Say It GUI software from the 30080 product page at www.parallax.com. Use the default installation path. For Windows Vista users, install as administrator. 3. Start the Say It GUI software, and then connect the Board of Education to your PC and turn the power switch on (position 1) ...
Page 3
... A PBASIC “bridge” program will automatically be downloaded to the BASIC Stamp 2. This bridge program allows the user to work with the set of SI commands the Say It module provides, as well as defining new commands. Copyright © Parallax Inc. Serial port to use Connect Icon Figure 2 Figure 3 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 4
... Copyright © Parallax Inc. Wordset 1 Wordset 2 0 action 0 left 1 move 1 right 2 turn run 3 down 4 look 4 forward 5 attack 5 backward 6 stop 7 hello Figure 4 Parallax Say It Module (#30080) Wordset 3 0 zero 1 one 2 two 3 three 4 four 5 five 6 six 7 seven 8 eight 9 nine 10 ten v1.0 4/14/2010 Page ...
Page 5
... Group – Groups of user-definable SD commands. You may add commands total (31 if you also define a trigger word). Password – A special group for “vocal passwords,” may be defined. Wordset – Built-in groups of Speaker Independent (SI) commands (Figure 3) Copyright © Parallax Inc. Test Group Figure 5 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 6
... Adding a SD command can be completed by doing the following while the Say It “bridge” program is running. 1. Select a group that you would like to add the word(s) to (Figure 6). Copyright © Parallax Inc. Figure 6 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 7
... Click “Add Command” from the tool bar or menu (Figure 7), and provide a label. In this example, the label “CREATE_LABEL_HERE” has been created; however it is suggested that you use a label that you can later review and know what the word is. Copyright © Parallax Inc. Add Command Figure 7 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 8
... If you are unhappy with the training, select erase training, and start the training process over from step 3 until satisfied. Copyright © Parallax Inc. Train Command Figure 8 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 9
... Once finished you will see a number next to the group you trained; indicating how many words belong to that group (Figure 9). Copyright © Parallax Inc. Figure 9 Figure 10 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 10
... Select the “Generate Code…” icon on the toolbar or from the menu (Figure 11) 2. You will be prompted to save the file to then edit within the BASIC Stamp Editor (Figure 12). Copyright © Parallax Inc. Generate Code Figure 11 Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 11
... Vdd at bottom P0 and LED to P4). 2. Open the sample code labeled “SayIt_Demo.BS2” in the BASIC Stamp Editor. Copyright © Parallax Inc. Figure 12 Parallax Say It Module (#30080) ® Robot v1.0 4/14/2010 Page ...
Page 12
... Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 13
... Copyright © Parallax Inc. Quantity Minimum 3.3 Function Ground Receive I/O Pin (TTL & CMOS compatible) Transmit I/O Pin (TTL & CMOS compatible) Red LED indicator No Connection No Connection Parallax Say It Module (#30080) Say It module back connection Typical Maximum 5.0 5.5 v1.0 4/14/2010 Page Units V ...
Page 14
... This is the back view of the module, the connection pins are indicated on the silkscreen. 5 VDC (Pin 10) no connect x no connect x no connect x no connect x no connect x Indicator LED Transmit pin Receive pin Ground (Pin 1) Module Dimensions 13.20 mm Copyright © Parallax Inc. No Connection No Connection No Connection 5 V regulated DC Parallax Say It Module (#30080) 63.22 mm v1.0 4/14/2010 Page ...
Page 15
... Knob level (0-4) Expected replies: STS_SUCCESS CMD_LEVEL “v” Sets Speaker Dependent (custom programmed commands) to specific level [1] Threshold (1-5) Expected replies: STS_SUCCESS CMD_LANGUAGE “l” Set Speaker Independent (pre-programmed commands) language Copyright © Parallax Inc. Parallax Say It Module (#30080) 26.21 mm v1.0 4/14/2010 Page ...
Page 16
... Remove Speaker Dependent (custom command) or Password recognition [1] Command position (0-31) Expected replies: STS_SUCCESS CMD_NAME_SD Give a label for a Speaker Dependent (custom programmed commands) or Password “n” command [1] Group index (0 = trigger, 1-15 = generic password [2] Command position (0-31) Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 17
... Expected replies: STS_SUCCESS Status Details STS_MASK “k” Mask of non-empty groups [1-8] 4-bit value that form a 32-bit mask, LSB first In replay to: CMD_MASK_SD STS_COUNT “c” Count of commands [1] Integer (0-31) In replay to: CMD_COUNT_SD Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 18
... Recognized Speaker Independent (pre-programmed commands) work or training a similar “s” Speaker Independent (pre-programmed commands) command [1] Wordset indext (0-31) In replay to: CMD_RECOG_SD, CMD_TRAIN_SD,CMD_RECOG_SI STS_OUT_OF_MEM “m” Memory Full Error In replay to: CMD_GROUP_SD STS_ID “x” Provide firmware ID Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...
Page 19
... Version ID (0) In replay to: CMD_ID Argument Mapping ARG_MIN “@” Minimum argument value (-1) ARG_MAX “ ‘ “ Maximum argument value (-1) ARG_ZERO “A” Zero argument value Copyright © Parallax Inc. Parallax Say It Module (#30080) v1.0 4/14/2010 Page ...