TCP404XL Tektronix, TCP404XL Datasheet

no-image

TCP404XL

Manufacturer Part Number
TCP404XL
Description
Test Probes Probe, DC-2MHz 500A DC, 750A DC
Manufacturer
Tektronix
Datasheet

Specifications of TCP404XL

Color
Black
Equipment Type
Test Probe Set
Accuracy
1% of Reading (Typ.)
Application
Semiconductor devices, power inverters⁄converters, electronic ballasts, industrial⁄consumer electronics, mobile communications, motor drives and transportation system
Bandwidth
2 MHz
Current, Rating
500 A Continuous
Impedence, Insertion
0.8 Ohms @ 1 MHz
Length, Cable
315 in.
Sensitivity
1 A⁄mV @ 750 A (Peak Pulse)
Standards
UL Listed, CSA Certified
Time, Rise
175 ns (Max.)
Voltage, Rating
500 Adc
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
1
A C / D C C u r r e n t M e a s u r e m e n t S y s t e m s
Increased Performance and Simplicity
The TCP300 and TCP400 series AC/DC Current
Measurement family is a highly advanced
current measurement system for today’s
current measurement needs. The split-core
probes incorporate both transformer and Hall
effect technology to provide broad bandwidth
measurement capabilities from DC up to
100 MHz at current levels as low as 1 milliamp
to thousands of amps (when used with CT4
current transformer). When connected to
Tektronix TDS Oscilloscopes with TEKPROBE
Level II or TekConnect (w/TCA-BNC) interfaces,
current measurements and calculations are
simple and easy.
Additional measurement power is available
with add-on software such as the TDSPWR2
power measurements package. With all this
measurement power current measurements
have never been easier.
Product Type
TCPA300
www.tektronix.com/accessories
TCP312
TCP305
TCP303
Meets Today’s AC/DC Current
Measurement Applications
The TCPA300 amplifier, when used with
TCP312, TCP305, or TCP303 probes, provide a
wide range of current measurement capability
and spans the gap between low level milliamp
measurements to very high current levels.
These three probes provide current measure-
ment capabilities of 30A, 50A, and 150A DC
continuous. For even higher current levels, the
TCPA400 amplifier with the TCP404XL current
probe measures 500A DC continuous and
750A DC continuous, derated with duty cycle.
Higher frequency performance is available with
the TCP312 w/TCPA300 providing 100 MHz
bandwidth and a maximum current of 30A DC.
TCPA400
TCP404XL
*
*
1
2
Derated with Duty Cycle.
Requires a TDS TEKPROBE Oscilloscope or a
TekConnect Oscilloscope with TCA-BNC.
AC/DC Measurement
Capabilities
DC – 100 MHz, Current Probe
Amplifier (TCPA300) Uses:
– DC – 100 MHz, 30 A DC
– DC – 50 MHz, 50 A DC
– DC – 15 MHz, 150 A DC
DC – 50 MHz, Current Probe
Amplifier (TCPA400) Uses:
– DC – 2 MHz, 750*
Direct Scaling and Units*
Oscilloscope On-screen
Readout Reduces
Measurement Errors by
Eliminating Hand Calculations
AC/DC Input Coupling
Low Insertion Impedance –
Reduces Device Under
Test Loading
Small Mechanical Package –
Less Desktop Space, Easier
Storage and Handling
Split-core Construction –
Allows Easy Circuit Connection
Status Indicators Provide
Notification of Potential
Error Conditions
Lower DC Drift and Noise
Certified for U.S., Canada,
and Europe
Development and Analysis
for: Power Supplies,
Semiconductor Devices,
Power Inverters/Converters,
Electronic Ballasts,
Industrial/Consumer
Electronics, Mobile
Communications,
Motor Drives,
Transportation Systems
Features & Benefits
Applications
(TCP312)
(TCP305)
(TCP303)
(TCP404XL)
(500 A DC Continuous)
1
A DC
2

Related parts for TCP404XL

TCP404XL Summary of contents

Page 1

... These three probes provide current measure- ment capabilities of 30A, 50A, and 150A DC continuous. For even higher current levels, the TCPA400 amplifier with the TCP404XL current probe measures 500A DC continuous and 750A DC continuous, derated with duty cycle. Higher frequency performance is available with the TCP312 w/TCPA300 providing 100 MHz bandwidth and a maximum current of 30A DC ...

Page 2

... Even non-TEKPROBE systems can use the TCPA 300/400 series to make proper current measurements by simply multiplying the measured output voltage on the oscilloscope by the TCPA 300/400 series range setting. TCP303 w/TCPA300 TCP404XL w/TCPA400 DC – 15 MHz A/V Range 150A 150A 500A ...

Page 3

... R.H. +30 ºC to +75 ºC (86 ºF to 167 ºF) 2000 m (6800 ft.) maximum 12,192 m (40,000 ft.) maximum TCPA300 TCP312 TCP305 TCP303 • • • TCP303 w/TCPA300 TCP404XL w/TCPA400 UL3111-2-032 ; UL3111-1 (Probe and Amplifier) CAN/CSA C22.2 No.1010.2.032 CAN/CSA C22.2 No.1010.1 (Probe and Amplifier) EN61010-1/A2; EN61010-2-032 EN61010-1/A2 (Probe and Amplifier) IEC61010-2-032 IEC61010-1/A2 ...

Page 4

... Opt. R5 – Repair Service 5 Years. Recommended Accessories 016-1923-00 – Cover, small Probe Protective; (for TCP305, TCP312, A6302, A6302XL, A6312, TCP202). 016-1924-00 – Cover, large Probe Protective; (for TCP303, TCP404XL, A6303, A6303XL, A6304XL). 016-1922-00 – Case, transit; Current Measurement Systems. 011-0049-02 – 50 feedthrough termination. 012-0117-00 – 50 BNC-to-BNC coaxial cable. 012-1605-00 – ...