PIC18LF452 Microchip Technology, PIC18LF452 Datasheet - Page 55

no-image

PIC18LF452

Manufacturer Part Number
PIC18LF452
Description
(PIC18LFxx2) Enhanced FLASH Microcontrollers
Manufacturer
Microchip Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18LF452-I/L
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18LF452-I/P
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
PIC18LF452-I/PT
Manufacturer:
XILINX
Quantity:
349
Part Number:
PIC18LF452-I/PT
Quantity:
6
Part Number:
PIC18LF452-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18LF452-I/PT
Manufacturer:
HAR
Quantity:
15
Part Number:
PIC18LF452-I/PT
Manufacturer:
MICROCH
Quantity:
20 000
Part Number:
PIC18LF4520-E/PT
Manufacturer:
SIEMENS
Quantity:
2
Part Number:
PIC18LF4520-I/ML
Manufacturer:
MICROCHI
Quantity:
20 000
Part Number:
PIC18LF4520-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18LF4520-I/PT
Manufacturer:
MICROCHI
Quantity:
20 000
Part Number:
PIC18LF4520T-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
Part Number:
PIC18LF4523-I/ML
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
PIC18LF4525-I/PT
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
4.14
The Reset Control (RCON) register contains flag bits
that allow differentiation between the sources of a
device RESET. These flags include the TO, PD, POR,
BOR and RI bits. This register is readable and writable.
REGISTER 4-3:
2002 Microchip Technology Inc.
RCON Register
bit 7
bit 6-5
bit 4
bit 3
bit 2
bit 1
bit 0
RCON REGISTER
bit 7
IPEN: Interrupt Priority Enable bit
1 = Enable priority levels on interrupts
0 = Disable priority levels on interrupts (16CXXX Compatibility mode)
Unimplemented: Read as '0'
RI: RESET Instruction Flag bit
1 = The RESET instruction was not executed
0 = The RESET instruction was executed causing a device RESET
TO: Watchdog Time-out Flag bit
1 = After power-up, CLRWDT instruction, or SLEEP instruction
0 = A WDT time-out occurred
PD: Power-down Detection Flag bit
1 = After power-up or by the CLRWDT instruction
0 = By execution of the SLEEP instruction
POR: Power-on Reset Status bit
1 = A Power-on Reset has not occurred
0 = A Power-on Reset occurred
BOR: Brown-out Reset Status bit
1 = A Brown-out Reset has not occurred
0 = A Brown-out Reset occurred
Legend:
R = Readable bit
- n = Value at POR
R/W-0
IPEN
(must be set in software after a Brown-out Reset occurs)
(must be set in software after a Power-on Reset occurs)
(must be set in software after a Brown-out Reset occurs)
U-0
U-0
W = Writable bit
’1’ = Bit is set
R/W-1
RI
Note 1: If the BOREN configuration bit is set
2: It is recommended that the POR bit be set
U = Unimplemented bit, read as ‘0’
’0’ = Bit is cleared
(Brown-out Reset enabled), the BOR bit is
’1’ on a Power-on Reset. After a Brown-
out Reset has occurred, the BOR bit will
be cleared, and must be set by firmware to
indicate the occurrence of the next
Brown-out Reset.
after a Power-on Reset has been
detected, so that subsequent Power-on
Resets may be detected.
R-1
TO
R-1
PD
PIC18FXX2
x = Bit is unknown
R/W-0
POR
DS39564B-page 53
R/W-0
BOR
bit 0